SN Query

Language

Home2-Wire IP Video Intercom Distributor290AB
Quick Start Guide
1.Field Application

image.png

2. Connection Diagram

290A(2Wire IP Isolator):

image.png

290AB(Isolator):

image.png

Voltage: DC 48V

Rated power: 4W(290A)/2W(290AB)

Max connection:

Every 290A or 290AB support 60W power and connection to max 8 indoor monitors.

Distance: 100m, if there is cascade connection with 290AB, it can connect to max 24 indoor monitors.

50m, if there is cascade connection with 290AB, it can connect to max 32 indoor monitors.

Note: If more than 32 indoor monitors are required, please call DNAKE tech-supporting and customer center.

3. Installation Steps

Step 1. Hardware Check and Preparation

●Please check if there is any product defect.

●Prepare :

1) Network cable

2) 2Wire cable

3) 48VDC Power supply to 290A or 290AB.( Please check the cable length, spec, and connection status.)

4) 2.0/2.5mm Slot Screw Driver.

Step 2. Installation

●In general, 290A is set in weak power box on the first floor. Every unit has only one 290A to realize the function of management.

●Interface "Main In" is connected to outdoor panel and interface "Main Out" is used for cascade expansion of 290AB. Two network interfaces have switch function and support networking.

●Connect a 48V DC power supply into 290A or 290AB to provide power to the sub-system, including the outdoor panel and indoor monitor.

●AIll devices are in 2Wire Link Mode. They will find each other and establish basic level encrypted communication.

4. L ED Indicator

290A provides green and red LEDs to indicate the status of Link/Act.

1.Red LED means the connection status of 2-wire cable. If the red LED is always on, it means 2Wire Link Mode. If the LED flashes slowly, it means 2Wire Unlink Mode.

2.Green LED is the Ethernet connection indicator. When the module is transmitting or receiving through Ethernet, the LED toggles with 250ms period.

Prev Next