1. Network
Connect with management center, indoor monitor or other network equipment by network switch.
2. Power/Switching Value Output
Power interface of door station connects with 12V DC power. Switching value output connects with electric lock. Independent power supply is required for the lock.
3. RS485 Interface/ Exit Button/Door-detector Switch/Fire Fighting Linkage RS485 interface can connect to the equipment with RS485 interface, and output 12V/100mA power. DIN is reserved terminal, please don't connect it.
4. USB Interface
It is used to connect USB peripherals and supports connection with USB2.0 device.
It can output 5V / 50mA power supply.
5. Wiegand Interface
The interface can be connected to one IC card reader or be used for reading the information of built-in card reader. It can output the power你5V/100mA. When the card reader doesn't need the power from the interface, connection of +5V isn't required.
Note: Only one card reader can be connected to door station. When there is built-in card reader, the interface can only be used for reading the information of built-in card reader.